AQUATECH

アクアテック株式会社 AQUATECH wesite





HOME

About Jarikko Purification System


What Is Jarikko Purification System?




Comparison to Activated Sludge Method


Operation Instances of Jarikko Purification System


River Purification





Lake Purification




Industrial Wastewater Treatment




Community Plant Treatment




About Aquatech




Contact Us


Japanese
Lake Purification

Basic Design


Excavation
A concrete tank would obstruct the running water, if an unexpected flooding occurred.
Aeration
None.
Sludge Removal and Sludge Treatment
A sludge removal is done in winter.
Water Gathering Facility
Should be built with soil-sand-proofs.
Specifications
Actual Retention Time: 0.5h
Flow-Down Distance: 5m


Basic Structure


Jarikko Purification Facility is built outside the lake just like the one built for the river. The structure of the facility is the same as the structure of the one for the river.


List of Purification Results and Placement


Place
Operating Organization
Chlorophyll a (µg/l)
Raw Water
Purified Water
Removal Rate (%)
Yakushi Pond
Machida City
106
15
85.6
Kogai River
Japan Water Agency
10
4
63.5
Nomadai Pond
Fukuoka City
14
1
91.9
Tega Pond (Outflow Water)
Tone River Downstream Office
94
13
85.9
Noda City Park Pond
Noda City
50
10
80.0
Pompon Pond
Tatebayashi City
150
30
80.0
Tajimi Junior High School
Tajimi City
-
-
-